The 3D Revascularization Device™ is used in the treatment of acute ischemic stroke.
The 3MAX™ is an aspiration catheter designed for the treatment of acute ischemic stroke.
The 4MAX™ is an aspiration catheter designed for the treatment of acute ischemic stroke.
The 5MAX™ is an aspiration catheter designed for the treatment of acute ischemic stroke.
The Accero® stent is a 12 to 16-wire braided platinum-nitinol stent used in the treatment of wide-necked intracranial aneurysms.
The ACCLINO Flex Plus is the fourth generation of the ACCLINO stent used in the treatment of wide necked intracranial aneurysms.
The ACE™60 is an aspiration catheter designed for the treatment of acute ischemic stroke.
The ACE™64 is an aspiration catheter designed for the treatment of acute ischemic stroke.
The ACE™68 is an aspiration catheter designed for the treatment of acute ischemic stroke.
APERIO® Hybrid and APERIO® Hybrid¹⁷ are the third generation of the APERIO® thrombectomy device.
Apollo™ is a flow-directed microcatheter with a detachable tip designed to access the neurovasculature for the Onyx™ liquid embolic system injection.
The Armadillo is a guide catheter, specifically designed for the transradial approach.
ASAHI CHIKAI 0.08" and 0.010" are indicated to treat AVM and hypervascular tumors.
The ASAHI FUBUKI 043 is a Distal Access Catheter (DAC) used in neurovascular procedures.
ASAHI FUBUKI® is a stainless steel braided guiding used to access the neurovasculature.
The ASAHI FUBUKI® Long Sheat is used to access the neurovasculature either as a long sheath or a guide catheter.
Avigo™ microwire is built of stainless steel and has a medium support.
The AXS Catalyst™ is a Distal Access Catheter (DAC) that can also be used for aspiration in neurovascular procedures.
The AXS Infinity LS™ is a long sheath that is used to access the neurovasculature.
The AXS Offset™ is used in conjunction with a guide catheter to assist the navigation into the neurovasculature.
The AXS Vecta™ 71 is an aspiration catheter designed for the treatment of acute ischemic stroke.
The AXS Vecta™ 74 is an aspiration catheter designed for the treatment of acute ischemic stroke.
The ballast® is a 6F long sheath that is used to access the neurovasculature.
Baltacci is a flow-directed microcatheter indicated for use at AVM treatment with non-adhesive liquid embolic agents and glue.
The Benchmark™ 071 is a Distal Access Catheter (DAC) used in neurovascular procedures. This device has a flat and round variable coil design.
The BENCHMARK™ BMX™96 Access System is designed for today’s most complex neurovascular interventions.
The Cascade™ device provides non-occlusive support during coil embolization of intracranial aneurysms.
Second generation of self-expanded carotid stents (dual layer).
The Catch + is a laser-cut closed-cell design stent retriever used in the treatment of acute ischemic stroke.
The Cathchview a laser-cut, closed-cell design stent retriever used in the treatment of acute ischemic stroke.
The CELLO™ is a balloon guide catheter used for vessel flow arrest during the treatment of acute ischemic stroke.
CerusEndo MC021 microcatheter is with Teflon-lined ID for optimal interaction with intraluminal devices. It is usually used to deliver stents, intrasaccular devices, and flow diverters.
The Chaperon™ is a metal braided guide catheter used to access the neurovasculature.
Contour Neurovascular System™ is an intrasaccular that provides a combination of flow diversion at the neck of the aneurysm and flow disruption within the aneurysm sa
The Copernic2L is a compliant dual lumen balloon indicated to treat sidewall aneurysms, angioplasty to treat vasospasm, and balloon test occlusion.
Copernic™ RC is the unique balloon catheter specifically developed for navigation in the dural sinuses.
The CREDO® is a closed-cell nitinol stent with high outward radial force used in the treatment of intracranial atherosclerotic disease.
Derivo® and Derivo® mini are flow diverter stents composed of 48 nitinol wires with a platinum core.
The Distal Delivery Catheter (DDC) is used as a guiding catheter to access the neurovasculature. This device comes in two options, the 4MAX DDC and the 5MAX DDC.
Echelon™ microcatheter is made of polymer compost with nitinol reinforcement braid and is commonly used to delivery coils.
The system comprises an eCLIPs™ Implant, an eCLIPs™ Delivery Wire, and an eCLIPs™ Sheath.
The Eclipse2L is a super compliant dual lumen balloon indicated to treat sidewall and bifurcation aneurysms, angioplasty to treat vasospasm, and balloon test occlusion.
The ERIC® device is an interlocking spherical stent retriever used in the treatment of acute ischemic stroke.
Excelsior® 1018® has a variable stainless-steel coil design.
Excelsior® SL-10® has a variable stainless-steel coil design. Its outer diameter is also variable with a proximal supportive shaft of 0.032” and a low-profile distal tip of 0.023”.
Excelsior® XT-27® is a microcatheter used in neurovascular procedures. It has a nitinol cross-helix braid design.
Excelsior™ XT-17™ is microcatheter used in neurovascular procedures. It has a nitinol cross-helix braid design.
The FARGO is a Distal Access Catheter (DAC) used in neurovascular procedures. The device has a progressive braided design.
The FARGO MAX is a Distal Access Catheter (DAC) used in neurovascular procedures. This device has a progressive braided design.
The FARGO MINI is a Distal Access Catheter (DAC) used in neurovascular procedures. This device has a progressive braided design.
The Flexor® Shuttle® is a long sheath that is used to access the neurovasculature.
The FlowGate2™ is a balloon guide catheter used for vessel flow arrest during the treatment of acute ischemic stroke.
The FRED® device is a nitinol self-expanding flow diverter stent. It has a unique dual layer construction in order to achieve better vessel wall apposition.
Gama17 is a microcatheter usually used to delivery intracranial stents (recommended by manufacturer for Leo+ baby), flow diverters (recommended by manufacturer for Silk Vista Baby), stent retriever (recommended by manufacturer for Catch+ mini and Catch view mini, and coils (recommended by manufacturer for Optima coils).
The Gateway® is an over-the-wire PTA Balloon specially designed to treat intracranial stenosis.
Guider Softip is a stainless steel braided guiding used to access the neurovasculature.
Headway® is a microcatheter used in a broad range of neurovascular procedures. It comes in two general versions, the Headway® and the Headway® DUO.
Hybrid is a microwire which is used in a broad range of Interventional Neuroradiology procedures, once it is available from 0.007" to 0.0014" in diameter.
HyperGlide™ is a compliant balloon that is indicated to treat sidewall aneurysms
The JET™ 7 is an aspiration catheter designed for the treatment of acute ischemic stroke.
The Leo plus stent is a braided nitinol stent designed for use in the treatment of wide-necked intracranial aneurysms.
The Leo Baby stent is a braided nitinol stent designed for use in the treatment of wide-necked intracranial aneurysms. The Leo Baby is the smaller diameter version of the Leo stent.
The L-VIS Jr. is a Nitinol stent designed for use in the treatment of wide necked intracranial aneurysms.
The LVIS™ is a nitinol stent designed for use in the treatment of wide necked intracranial aneurysms.
Magic is a flow-directed microcatheter usually used to treat arteriovenous shunts.
Magic Glue is an adhesive embolic agent composed of n-hexyl cyanoacrylate monomers.
Marathon™ is a flow-directed microcatheter designed to access the neurovasculature for the Onyx™ liquid embolic system.
Marksman™ microcatheter is made of polymer compost with stainless-steel reinforcement braid and is commonly used to deliver intracranial stents and flow diverters.
The Merci is a balloon guide catheter used for vessel flow arrest during the treatment of acute ischemic stroke.
The Mirage™ microwire is specially designed to navigate through small distal vessels and complex neurovascular anatomies.
The Navien™ a Distal Access Catheter (DAC) used in neurovascular procedures. This device has a flat nitinol coil design with variable stiffness.
Neqstent is an intrasaccular coil-assisted flow diverter.
The NeuroBridge® is a Distal Access Catheter (DAC) used in neurovascular procedures.
The Neuroform Atlas™ is a nitinol stent designed for the treatment of wide-necked intracranial aneurysms.
The Neuroform EZ® is an open-cell nitinol stent designed for the treatment of wide-necked intracranial aneurysms.
The Neuron Max is a long sheath that is used to access the neurovasculature.
The Neuron® is a Distal Access Catheter (DAC) used in neurovascular procedures.
NeuroSlider® is a microcatheter with a hybrid reinforcement design, combining coil and braid for flexibility, torquability, and support.
The NeuroSpeed® is an over-the-wire Dual Lumen Balloon specially designed to treat intracranial stenosis.
The NeVa™ is a novel thrombectomy device used in the treatment of acute ischemic stroke.
Onyx™ is a non-adhesive liquid embolic agent (LEA) based on Ethylene Vinyl Alcohol (EVOH) copolymer.
P48MW is a flow diverter stent composed of 48 nitinol wires with a platinum core, designed to treat distal anatomies (vessel diameters from 1.75 mm to 3 mm).
P64MW is a flow diverter stent composed of 64 nitinol wires with a platinum core.
pCONUS is a nitinol stent-like implant designed to treat wide-neck bifurcations aneurysms.
The Penumbra Select Catheter is designed to assist in the navigation into the neurovasculature.
Phenom microcatheters are designed with a variable dual stainless-steel brain.
The Phenom™ PLUS is a Distal Access Catheter (DAC) used in neurovascular procedures.
PHIL™ (Precipitating Hydrophobic Injectable Liquid) is a non-adhesive Liquid Embolic Agent (LEA) composed of 2 specific copolymers: polylactide-co-glycolide and polyhydroxyethylmethacrylate. Its solvent is Dimethyl Sulfoxide (DMSO).
The Pinnacle® Destination® is a long sheath used to access the neurovasculature.
Pipeline™ Flex is a flow diverter stent composed of 48 wires (36 cobalt-chromium wires and 12 platinum-tungsten).
Pipeline Flex™ with Shield Technology is a flow diverter stent composed of 48 wires (36 cobalt-chromium wires and 12 platinum-tungsten).
The pITA® RX Neuro PTA Balloon Catheter is a Rapid Exchange PTA Balloon specially designed to treat intracranial stenosis
The pORTAL microwire is built with a super-alloy ASACOR, a new alloy designated to optimize the performance in complex cases, balancing the guidewire in support and flexibility.
First generation of self-expanded carotid stents.
pRELAX is a temporary stent for the treatment of intracranial vasospasm.
The pRESET and pRESET LITE are closed-cell laser-cut stent retrievers used in the treatment of acute ischemic stroke.
The PX SLIM™ is a microcatheter designed for the deployment of Penumbra's large volume coils (PC 400™, POD 400™, and PAC 400™).
The React™ 68 is an aspiration catheter designed for the treatment of acute ischemic stroke.
The React™ 71 is an aspiration catheter designed for the treatment of acute ischemic stroke.
Rebar™ is a microcatheter are made of continuous stainless-steel.
RED® 62 is an aspiration catheter used to perform mechanical thrombectomy in patients with ischemic stroke.
RED® 68 is an aspiration catheter used to perform mechanical thrombectomy in patients with ischemic stroke.
RED® 72 is an aspiration catheter used to perform mechanical thrombectomy in patients with ischemic stroke.
Rist™ 079 is a guiding catheter specifically designed for the transradial approach.
Rist™ Selective Catheter is a device used to track guiding catheters and long sheaths.
Scepter C® is indicated to treat sidewall aneurysms. Scepter XC® is indicated to treat bifurcations aneurysms as it can expand asymmetrically.
Silk + is a flow diverter stent composed of 48 nitinol wires. It is designed for the treatment of intracranial aneurysms in association with embolization coils.
Silk and Silk Vista Baby are flow diverter stents composed of 48 nitinol wires with a platinum core.
The SOFIA™ is a Distal Access Catheter (DAC) used in neurovascular procedures.
The SOFIA™ plus is an aspiration catheter designed for the treatment of acute ischemic stroke.
The Solitaire™ AB is a self-expanding detachable nitinol stent used in the treatment of wide-necked intracranial aneurysms.
The Solitaire™ Platinum is the third generation of the Solitaire™ device, used for the treatment of acute ischemic stroke.
The Solitaire™ X is the fourth generation of Solitaire™ device, used for the treatment of acute ischemic stroke.
Sonic is a flow-directed microcatheter with a detachable tip designed to access the neurovasculature for the Squid injection.
Squid is a non-adhesive liquid embolic agent (LEA) based on Ethylene Vinyl Alcohol (EVOH) copolymer. Its solvent is Dimethyl Sulfoxide (DMSO), and suspended micronized tantalum powder provides its radiopacity.
Surpass Evolve is a flow diverter stent composed of 64 Cobalt-chromium and platinum-tungsten wires, except for the 2.5mm, which has 48 wires.
Surpass™ Streamline™ is a flow diverter stent composed of Cobalt-chromium and platinum-tungsten wires.
The Synchro® microwire has a platinum-tungsten coil for distal visualization (distal 15cm in Synchro 14 and distal 10cm in Synchro2®).
Transend® is built with stainless steel, and it is available with 0.010" and 0.014".
Transform® compliant is indicated to treat sidewall aneurysms.
Traxcess™ 14 has a hybrid alloy composed of stainless steel and nitinol.
The Trevo NXT is a stentretriver device used in the treatment of acute ischemic stroke. The Trevo NXT is the newest version of the Trevo device following the Trevo XP model.
Trevo® XP is a closed-cell stent retriever device used in the treatment of acute ischemic stroke.
Vasco+ is a microcatheter designed to provide access and support in the treatment of intracranial aneurysms and mechanical thrombectomy.
Velocity® is a microcatheter designed for the deployment of the 3D Revascularization Device.
The Vena Balloon Distal Access Catheter™️ has combined a distal access catheter and a balloon guide catheter into one, bringing the balloon closer to the clot. This concept aims to reduce residual clots, increase the first pass success rate, and cut costs.
The Walrus is a balloon guide catheter used for vessel flow arrest during the treatment of acute ischemic stroke.
The WEB™ device is an Intrasaccular Flow Disruptor device used for the treatment of intracranial aneurysms.
The Wedge™ microcatheter is used as an inner catheter to decrease the ledge effect in large bore aspiration catherters like the Sofia 6F.
The Wingspan stent is a nitinol open-cell stent with high outward radial force, used in the treatment of intracranial atherosclerotic disease.
X-Pedion™ is a microwire built with stainless steel.