Find a device
Disclaimer: The devices listed on this website may not be approved for use in your region. For further information, consult with the regulatory agency in your country.
The AXS Catalyst™ is a Distal Access Catheter (DAC) that can also be used for aspiration in neurovascular procedures.
The AXS Infinity LS™ is a long sheath that is used to access the neurovasculature.
The AXS Offset™ is used in conjunction with a guide catheter to assist the navigation into the neurovasculature.
The AXS Vecta™ 71 is an aspiration catheter designed for the treatment of acute ischemic stroke.
The AXS Vecta™ 74 is an aspiration catheter designed for the treatment of acute ischemic stroke.
Excelsior® 1018® has a variable stainless-steel coil design.
Excelsior® SL-10® has a variable stainless-steel coil design. Its outer diameter is also variable with a proximal supportive shaft of 0.032” and a low-profile distal tip of 0.023”.
Excelsior® XT-27® is a microcatheter used in neurovascular procedures. It has a nitinol cross-helix braid design.
Excelsior™ XT-17™ is microcatheter used in neurovascular procedures. It has a nitinol cross-helix braid design.
The FlowGate2™ is a balloon guide catheter used for vessel flow arrest during the treatment of acute ischemic stroke.
The Gateway® is an over-the-wire PTA Balloon specially designed to treat intracranial stenosis.
Guider Softip is a stainless steel braided guiding used to access the neurovasculature.
The Merci is a balloon guide catheter used for vessel flow arrest during the treatment of acute ischemic stroke.
The Neuroform Atlas™ is a nitinol stent designed for the treatment of wide-necked intracranial aneurysms.
The Neuroform EZ® is an open-cell nitinol stent designed for the treatment of wide-necked intracranial aneurysms.
Surpass Evolve is a flow diverter stent composed of 64 Cobalt-chromium and platinum-tungsten wires, except for the 2.5mm, which has 48 wires.
Surpass™ Streamline™ is a flow diverter stent composed of Cobalt-chromium and platinum-tungsten wires.
The Synchro® microwire has a platinum-tungsten coil for distal visualization (distal 15cm in Synchro 14 and distal 10cm in Synchro2®).
Transend® is built with stainless steel, and it is available with 0.010" and 0.014".
Transform® compliant is indicated to treat sidewall aneurysms.
The Trevo NXT is a stentretriver device used in the treatment of acute ischemic stroke. The Trevo NXT is the newest version of the Trevo device following the Trevo XP model.
Trevo® XP is a closed-cell stent retriever device used in the treatment of acute ischemic stroke.
The Wingspan stent is a nitinol open-cell stent with high outward radial force, used in the treatment of intracranial atherosclerotic disease.
Contact us and we help you find more details about the device you want